Depth of penetration in eddy current testing

Calculate the standard depth of penetration δ and the effective depth 3δ for any frequency, conductivity and permeability, and check whether your part is thick enough for the chosen frequency.

100 Hz – 10 MHz, logarithmic scale
1 for non-ferromagnetic materials (aluminum, copper, titanium, austenitic stainless)
mm
Cross-section of the part with eddy current density decreasing with depth
Standard depth δ (1/e, 37 %)
Effective depth 3δ (5 %)
Phase lag at the back wall

Frequency series for this material

Frequencyδ (mm)3δ (mm)Min. thickness ≥ 3δ
Same series as the Foerster tables: the chosen frequency and its multiples ×½, ×2, ×4, ×8, ×16. Doubling the frequency reduces δ by a factor of √2.

δ versus frequency

What frequency do I need to reach a given depth?

Formula: δ = 1 / √(π · f · μ₀ · μᵣ · σ)  →  δ [mm] = 503.3 / √( f [Hz] · σ [MS/m] · μᵣ ). Current density falls as e−x/δ and the phase lags by x/δ radians (57.3° per δ). At the effective depth 3δ, 5 % of the surface density remains; that is why 3δ is taken as the minimum thickness for the part to behave as “infinitely thick”. 100 % IACS = 58 MS/m.