What are FMC, TFM, PCI and PWI in phased array?

What each one is, how it works and why it matters in inspection — explained visually and interactively. Training material from LLOG NDT Academy.

Picture 64 people standing in a row, each holding a lamp and a recorder, facing a dark piece of steel. Everything that follows is that idea, in three steps.

1 · FMC — Capturing the data

One element fires alone; all of them listen and record. Then the next one, and the next. At the end: 64 × 64 = 4,096 recordings. This is only data collection — there is no image yet.

firing element / emitted wave defect and its echo element that has heard the echo
Step 1 · Element 1 fires alone, the others only listen

2 · TFM — The image, pixel by pixel

The computer goes through the part point by point and asks the recordings: "Did all of you hear an echo coming from exactly here?" If yes → hot pixel. If not → pale pixel. Because every pixel gets its own question, the image is perfectly focused everywhere — the defect shows its real shape, not a blob.

TFM asks point by point: was there an echo from HERE?

3 · PCI — Agreement instead of loudness

TFM adds up the loudness of the echoes — and deep defects sound faint (attenuation). PCI changes the question: not "how loud?" but "do all the recordings agree on the exact moment?" A microcrack (HIC, HTHA) sounds faint but agrees perfectly → it shines just like a large defect. And the back wall, which shouts but without agreement, disappears. Move the slider:

Same 3 defects, two ways of adding up
Defect depth

4 · PWI — Speed

FMC fires 64 times per frame with weak emissions: scanning a full line becomes slow. PWI fires all elements at once, forming a tilted plane wave — a few strong shots cover the same zone. The same TFM reconstruction afterwards, at several times the speed. Watch the frame counters:

Why does it matter to have it on your instrument?

FMC / TFM

Problem: conventional PAUT focuses at ONE depth; defects show up as blobs.

Perfect focus at every pixel: a crack looks like a crack. More realistic sizing, fewer unnecessary repairs, images the client understands at a glance.

Reliable characterization

PCI

Problem: deep or fine defects (HIC, HTHA) sound faint and amplitude misses them.

It measures agreement, not loudness: the microcrack shines as brightly as a large one and the back wall disappears. Early detection in H2S service — before the leak, not after.

Detects what others miss

PWI

Problem: FMC is slow for scanning entire lines and tanks.

A few strong plane-wave shots: near-TFM quality at several times the speed, with a better signal in attenuating materials.

More meters per shift
One scan, three readings. All three modes read the same FMC data: TFM for shape, PCI for detection, PWI for speed. Technical note: PCI is a detection and characterization tool, not a sizing tool — the correct workflow is PCI to find, TFM to size.