Eddyfi Floormap X

MFL Array multi-technology scanner for tank bottoms. Using STARS technology, it detects corrosion on both the top and bottom surfaces and inspects plates up to 20 mm thick, including the critical zone.

STARS Technology
Thickness: 20 mm
Critical Zone
On-site reports
Floor Map
Floor Map

Key features

  • MFL array with 256 Hall-effect sensors and 64 channels for high-resolution imaging.
  • STARS technology that detects corrosion on both the top and bottom surfaces of the tank bottom.
  • Active steering that inspects the critical zone up to 12 mm from the tank wall.
  • SmartMAGNET adjusts the magnetic flux to the thickness and allows the magnets to be turned off.
  • Simulated laser guide in the C-scan to locate and mark defects on the tank bottom.
  • Detachable tablet with SIMS GO and reports compliant with EEMUA 159 and API 653.
Plate thickness4 to 20 mm
Scan width300 mm
SpeedUp to 1 m/s
CoverageUp to 263 m²/h
Sensors256 sensors · 64 channels

General

MethodEddy Currents
BrandEddyfi

Screen

TypeDetachable touchscreen tablet
Display ModesLive C-scan of MFL Array and STARS

Measurement

Measurement TechniquesMFL Array (magnetic flux leakage) and STARS (magnetic field reluctance)
Sensors256 Hall-effect sensors, 64 channels
Measurement range4 to 20 mm (0.157 to 3/4 in) plate thickness
Detection Capability20%, Ø 2 mm (Ø 0.080 in)
Face DiscriminationYes, top and bottom, using STARS
CoatingsUp to 10 mm (0.394 in), non-magnetic
Scanning Speed0.5 to 1 m/s (19.7 in/s to 3.28 ft/s), variable
Scan width300 mm (12 in)
Scan CoverageUp to 263 m²/h
Critical ZoneUp to 12 mm (1/2 in) from the tank wall
Scan ModesMapping, Freescan, and Default Pause
ScrollCD drive with antistatic wheels or manual feed

Evaluation

FeaturesAutomated and editable list of instructions, interactive laser guide, pause on error
Magnetic FluxVariable and deactivatable SmartMAGNET, rare-earth magnets

Data

Data Acquisition SoftwareSIMS GO
PC softwareSIMS PRO, analysis and reports

Power

Battery3 packages
Battery lifeUp to 4 hours of battery life
Charger1 charger, for continuous operation

Environmental

Operating temperature−10 to 45 °C
Storage temperature−35 to 60 °C (−31 to 140 °F)

Physical

Weight57.5 kg (126 lb) in operation
Minimum Access500 mm (20 in), manway
AxleAdjustable height
LightingAdjustable front LEDs and rear LEDs

Standards

ComplianceEEMUA 159 and API 653 (reports)

Includes

Batteries3 batteries
Charger1 charger
Cases2 carrying cases
Oil and gas