FOERSTER MAGNETOSCOP 1.070

A microprocessor-controlled portable magnetometer that measures magnetic flux density and relative magnetic permeability using fluxgate probes, either as absolute values or as gradients.

Fluxgate sensors
Permeability Measurement
SD Card Recording
Portable and lightweight
Magnescop
Magnescop 1,070

Key features

  • Measures magnetic flux density as an absolute value or as a gradient.
  • Determines the relative permeability μr from 1.0 to 2.0 using the probe method.
  • Automatic recognition of calibrated probes for quick setup.
  • Single and batch measurements, peak detection, and visual and audible alarms.
  • Editable measurement procedures with a graphical guide for the operator.
  • Data stored on an SD card and transferred via USB to the MAGDATA software.
Field Range0.1 nT to 50 mT
Permeabilityμr 1.0 to 2.0
Weight0.62 kg with batteries

The MAGNETOSCOP 1.070 It is a portable, microprocessor-based magnetometer system with probes for measuring magnetic flux density as an absolute or differential (gradient) value. It features a USB port for easy data transfer and an SD card for storing measurement data and parameters. The measurement system also allows for the identification and storage of maximum values and the setting of thresholds for limit values. The unit can be used for individual or serial measurements. The data can be easily analyzed and documented using the PC software included in the scope of delivery. The MAGNETOSCOP 1.070 facilitates rapid, portable measurement of relative permeability in the field of quality control for stainless steel and low-permeability (non-magnetic) alloys, as well as the detection of ferrite domains. Changes in the material (sulfidation, rolling degradation, structural changes) can also be demonstrated through comparative permeability measurements.

Your benefits at a glance:

– Microprocessor-controlled portable magnetometer system.
– Measures magnetic flux density, absolute value, or gradient.
– Probe for measuring relative permeability µr in accordance with IEC 60404-15 and ASTM A342M.
– 3.5″ color display.
– USB interface for data transfer.

Technical specifications:

Measurement range: 0.1 nT to 50 mT.
µr: 1.0 to 2.0.
Field measurement uncertainty: 1.5% of the measurement range.
Permeability measurement uncertainty: 5% of the measured value.
Resolution: 24-bit ADC.
Dimensions of the measuring instrument: 221 x 102 x 41 mm.
Weight of the measuring instrument including batteries: 0.62 kg.
Protection rating: IP 54.
Ambient temperature: 0 to 40 °C.
Battery type: 4 x Mignon, AA, LR6.

 

Rules:

1. IEC 60404-15 Section 6: Describes the determination of relative permeability µr in the range from 1.0 to 2.0 using the probe measurement method. The described method is advantageous because it allows for the measurement of finished materials and components directly on the job site, without the need to fabricate special test specimens.

2. ASTM A342M Method 4: Describes the determination of relative permeability µr in the range of 1.0 to 2.0 using the probe measurement method. Like the previous method, it is advantageous because it allows for the measurement of finished materials and components directly on-site, without requiring special test specimens.

3. STANAG 2897 and AEODP-7: These standards specify the framework for testing nonmagnetic tools used in explosive ordnance disposal (EOD). The test method is based on measuring the residual magnetic field of the components under test using an absolute or gradient magnetometer.

4. API Spec 7: Describes the testing of oil drilling platforms to detect nonmagnetic properties. The test method is based on the measurement of the residual magnetic field and the relative permeability µr.

5. VG 95578: Describes the determination of relative permeability µr in the range of 1.0 to 2.0 using the probe measurement method. Like the previous methods, it is advantageous because it allows for the measurement of finished materials and components directly on the job site, without requiring special test specimens.

General

BrandFoerster
MethodEddy Currents

Display

Size3.5 in

Measurement

Measurement Range0.1 nT to 50 mT (magnetic field); μr 1.0 to 2.0 (permeability)
Measurement TechniquesMagnetic flux density (absolute or gradient) and relative permeability μr using the probe method
Accuracy1.5% of the measurement range (magnetic field); 5% of the measured value (permeability), expressed as uncertainty
A/D Converter24 bits
CalibrationCalibrated probes with certificate and stored calibration data; traceable to national standards

Evaluation

FunctionsIndividual and batch measurements, peak value detection, threshold monitoring, visual and audible alarms, editable procedures with graphical guidance, automatic probe recognition

Data

StorageSD card (measurement data and parameters)
Data LoggerIntegrated
File Formats.txt, .csv, .xml, .tdm (LabVIEW), export with MAGDATA
PC SoftwareMAGDATA: TRANSFER module included; optional HOTSPOT, MAGNETOMAT, and DLL modules
Software RequirementsWindows 7 or later, 32/64-bit, .NET Framework 4.5 or later
Software LanguagesGerman and English
LicensesDongle required for HOTSPOT and MAGNETOMAT; multiple licenses on a single dongle
ReportsSingle measurements, batch measurements, and API Spec 7
HotSpot AssessmentUp to 16 simultaneous graphs; threshold values, markers, and offset compensation

Connectivity

PortsUSB

Power

Battery4 x 1.5 V AA alkaline batteries (IEC LR6) or 4 x 1.2 V AA NiMH batteries, 2,850 mAh
Battery LifeApprox. 4 hours on batteries; over 10 hours with the POWER KIT and a power bank with a capacity of over 10,000 mAh
Other SourcesMains power; USB-A power bank with POWER KIT

Environmental

Protection RatingIP54
Operating temperature0 to 40 °C

Physical

Dimensions221 × 102 × 41 mm
Weight0.62 kg with batteries

Standards

ComplianceIEC 60404-15, Section 6; ASTM A342M, Method 4; STANAG 2897 and AEODP-7; API Spec 7; VG 95578

Includes

MAGDATA TRANSFERSoftware module for communication, data import/export, and firmware updates

Probes

PD-100-100Differential probe, 1 nT to 100 μT; sensor spacing 100 mm; length approx. 208 mm; cable approx. 3 m; large-scale anomalies; compensates for the Earth's magnetic field
PD-100-20Differential probe, 10 nT to 100 μT; sensor spacing 20 mm; length approx. 104.5 mm; tip Ø 6.5 mm; cable approx. 3 m; local anomalies and remanence
PFD-100Absolute or differential probe, 1 nT to 100 μT / 200 μT; sensor length approx. 60 mm; cable length approx. 3 m; residual field and remanence in components
PF-1000Absolute probe, 10 nT to 1 mT; sensor approx. 60 × 4.6 × 3.5 mm; axial alignment; cable approx. 3 m; field strength and direction
PP-2-5Permeability probe, μr 1.00000 to 2.00000; housing approx. 65 × 27 mm; cable approx. 3 m; IEC 60404-15 and ASTM A342/A342M

Optional Accessories

MAGNETOSCOP POWER KITCarrying case with transparent front panel and 150 mm USB-A cable
Power BankOver 10,000 mAh, USB-A
Power bank chargerFor the POWER KIT power bank

Optional accessories

Belt PouchWith an 800 mm USB-A cable
Non-magnetic mountFor PFD-100 probe
Permeability reference standardsØ 34.2 mm × 25 mm; individually certified μr (e.g., 1.0055 / 1.0368 / 1.153); reference field strength 30 kA/m
MAGDATA HOTSPOTVisualization, HotSpot analysis, and API Spec 7 reports
MAGDATA MAGNETOMATMAGNETOMAT data acquisition, visualization, and evaluation
MAGDATA DLLSystem integration into customer applications
Oil and gas
Power generation
Aerospace